The onsite bores delivered raw water which was high in conductivity, total dissolved solids, sodium, chloride, iron and aluminium which needed to be removed to meet Australian Drinking Water Guidelines.
The process that was recommended, and accepted by Origin Enery included; pre-treatment, ultra-filtrition (UF), reverse osmosis (RO), carbon filtration and disinfection.
Treated Water Production: 120kL / day